1. Why turtles are harder than fish of the same mass
Two differences dominate, and neither is about how much they poop in the abstract:
- Mechanical load. Turtles eat messily. A large share of food ends up as fragments in the water, which decay and consume oxygen while loading the mechanical stage of the filter. A filter that is merely "big enough" biologically can still clog weekly.
- Waste form. Turtle waste is bulky and breaks into suspension easily, so the filter's mechanical capture efficiency matters as much as its biological capacity.
This is why the common turtle recommendation is 3–5× turnover per hour, versus 2–3× for a comparable fish tank. It is a rule about solids, not about ammonia maths.
2. Flow is not the same as filtration capacity
Nitrification happens on surfaces. The capacity of a biofilter scales with media surface area and oxygen supply, not with litres per hour. A high-flow filter with a thimble of media is a water mover; a low-flow filter packed with media is a biofilter. Most turtle setups fail on media volume, then get "fixed" by buying a bigger pump — which makes the mechanical stage clog faster.
| Tank | Turnover floor (3×/h) | Practical target (4–5×/h) | Media volume, rough |
|---|---|---|---|
| 75 L | 225 L/h | 300–375 L/h | 2–4 L |
| 150 L | 450 L/h | 600–750 L/h | 4–8 L |
| 300 L | 900 L/h | 1,200–1,500 L/h | 8–15 L |
Media figures are a planning range based on typical bio-media surface area; the bench series will publish measured flow decay with loaded media, which is the number that actually matters.
3. The number on the box is measured at zero head
Manufacturer flow ratings are typically taken with no lift, no hose restriction and clean media. In a real cabinet setup with 1 m of head and two 90° bends, losing 20–50% of the rated flow is normal. A filter rated 1,000 L/h can deliver 600–800 L/h in service, and less as media loads.
So the honest way to size a filter is: take the practical target, divide by a realistic derating (say 0.6–0.75), and then check whether the media volume is adequate. Buying on the box number alone overshoots on flow and undershoots on media.
4. What the bench will settle
Our filter flow series measures actual delivered flow for each unit, clean and with a standard aged load, at a stated head height. That converts the derating range above into per-product numbers — which is the only form in which this question can actually be answered.