1. What the heater is actually fighting
A heater does not "set" a temperature. It replaces heat that the tank loses to the room. Steady state is reached when heater output equals loss, and loss has two dominant paths in an open turtle tank:
- Evaporation. Latent heat of water is 2.26 MJ per litre. A typical open-top indoor tank loses 0.5–1.0 L/day; at 0.75 L/day that is 0.47 kWh/day, i.e. an average 20 W of continuous heat loss — summer and winter.
- Conduction and convection through glass. For uninsulated glass to room air, U is roughly 5–8 W/(m²·K). A 75 L tank has about 0.9 m² of wetted surface, so 18 W at a 4 K difference (22 °C room, 26 °C water).
Add them: about 38 W at ΔT = 4 K, and roughly 55–60 W at ΔT = 8 K (a cold room in winter, where evaporation also rises).
2. Why the rule of thumb over-sizes
3–5 W/gal is 0.8–1.3 W/L. Applied to 75 L that means 60–100 W — which is 1.6–2.6× the loss above. That is not a disaster: a 100 W heater at 38 W loss runs at ~38% duty, which is healthy. The problem is what the rule hides: wattage is not the thing that keeps your turtle safe. The thermostat is.
| Tank | Loss at ΔT 4 K | Loss at ΔT 8 K | Sensible heater | Time to 35 °C if thermostat sticks closed* |
|---|---|---|---|---|
| 40 L | ~22 W | ~33 W | 50 W | ~8.4 h |
| 75 L | ~38 W | ~58 W | 100 W | ~7.9 h |
| 150 L | ~65 W | ~100 W | 150–200 W | ~7.9 h |
| 150 L, 300 W (oversized) | — | — | — | ~5.2 h |
*Ignoring further loss to the room, which lengthens these figures. From 26 °C to 35 °C, t = m·c·ΔT / P with c = 4186 J/(kg·K).
3. The number that should worry you
A stuck-on heater takes a turtle tank from comfortable to dangerous in under eight hours for a correctly sized unit, and under six if you oversized it. That is why the fail-safe behaviour is the first thing our heater test series measures — not the wattage on the box.
Corollary: a heater with a good thermostat and modest wattage is safer than a high-wattage unit with a lazy one. Sizing up "for headroom" buys you a faster disaster, not more stability.
4. What this page does and does not claim
Everything above is arithmetic on published thermal properties and typical tank geometry. It is not a measurement of any specific heater, and the evaporation figure (0.5–1.0 L/day) is a range, not a constant — your room humidity and airflow move it. Our bench series measures the part arithmetic cannot tell you: whether a given thermostat actually holds a setpoint, and how it fails.